air flow test facility

test specimen
  • control valves and shut-off valves
  • air valves (air release, vacuum breaking)
  • safety and pressure relief valves
click to enlarge
applications
  • flow capacity and pressure losses
  • choking flow (gas expansion factor)
  • noise (turbulence, choking flow)
  • design optimization
features
  • test fluid: air
  • flow capacity:10 kg/s
  • maximum diameter: 300 mm (12")
  • length of test section:17 m
  • line pressure: up to 12 bar
test procedures

Testing takes place according to international standards (ISA, ISO, IEC, EN, VDMA). The flow is supplied by a large air reservoir (capacity 70 m3), pressurized by a compressor. An active gas control valve allows for a constant pressure and flow in the test section. For a high accuracy over a wide flow range the main line or a bypass is available. The actual flow conditions are converted to standard conditions, according to the standards.

accuracy
  • flow: within 2 % of measured value
  • absolute pressure: within 0,25 % of measured value
  • pressure difference: within 0,2 % of measured value
  • temperature: better than 0,22 oK of the measured value
  • sound pressure level: within 1 dB
more information

For more information contact Martin Boele.